CEM REDUCER 48®

Reduces the need for cement by 20 % and can reduce CO2 emissions by 48 % by switching from CEM I to CEM II cement. Instead of 50 kg, you can achieve a C20-F4 with just 40 kg. Your solution for climate-neutral and sustainable construction.

  • Compressive and flexural strength

    CT-C20-F4
  • Foot traffic

    after 2 days
  • Normal site traffic

    after 10 days
  • Minimum nominal thickness 2 kN/m²

    from 40 mm
  • Shrinkage

    SW 2
  • Energy efficiency class

    EC 1
  • Certification

    EC1 Plus according to Emicode
  • Cement reduction: 20 %
  • CO2 reduction: up to 48 %
DOSAGE & CEMENT QUANTITY
MIXING INSTRUCTIONS
Notes
POINT LOADS INFORMATIONS
AREAS OF APPLICATION
Downloads

DOSAGE

Compressive strengthCT-C20-F4
Dosage400 ml
Cement quantity40 kg
  • Do not exceed the maximum dosage of 500 ml.
  • The specifications refer to a standard mixing vessel with a net capacity of 200 litres and a filling quantity of approx. 320 kg screed sand.
  • The specification ‘after the X. Day’ does not include the day of installation.
  • The strength class depends on the quality of the screed sand used.

MIXING INSTRUCTIONS

  1. Shake the container well to mix the Retanol® Reducer 48 additive to a consistent colour before use, and then shake as required throughout the installation to maintain the consistency of the liquid (every 30 min).
  2. Fill half of mixing vessel with 0-4 mm screeding sand and required cement.
  3. Add CEM® Reducer 48 to the first mixing water (usually 5-10 litres), then fill the machine completely.
  4. Gradually add the required amount of residual water until a stiff-plastic consistency is achieved.
  5. Let the screed mix for a full 2 minutes.

SAND, WATER, CEMENT

  • Grading curve: Sand must be according to DIN 1045-2 A/B / BS 13139*, for the production of screed concrete, grain size range 0-4 mm
  • W/C value:Min 0,4, max. 0,6
  • Cement: Use of cement grade 42.5 R/N according to PCT cement release list
  • CO2 savings through cement selection:
    • CEM I-Cement: Reduces CO2 emissions by approx. 20 % compared to a standard mix with CEM I
    • CEM II-Cement: Reduces CO2 emissions by approx. 48 % compared to a standard mix with CEM I 

*UK only

PROCESSING INSTRUCTIONS

  • Working time: 60 minutes
  • Finishing time: 90 minutes
  • Outside temperature: +5 °C to +28 °C for screed, environment and substrate
  • Do not mix with other screed additives
  • Never reactivate screed that has already set with water

Airing

  • If the air humidity is 55 % or higher, ventilate 3-4 times a day for 20-30 minutes 24 hours after screed installation in order to achieve readiness for covering.
  • If the humidity is below 55%, contact PCT technical support to avoid cupping etc.

FURTHER PRODUCT FEATURES

  • Tension and shrinkage reduced according to SW 2
  • Density approx. 2,000 to 2,200 kg/m3
  • Better processing and lower peel resistance
  • Reduction of air content
  • Start ventilation after 1 day

Protective instructions during and after installation

  • We recommend our PROTEC-ES/SP product to protect against drying out too quickly, depending on the floor covering. We recommend consulting the PCT technical support team.
  • Protect the screed against rapid drying of the surface due to draughts, sunlight and low humidity.
  • Large window fronts and floor-level glass façade areas should be darkened if necessary.
  • Cover screeds in outdoor areas or enclose areas to be covered. Contact PCT technical support if screed is to be laid outdoors.

CM MEASUREMENT

  • A screed with CEM® Reducer 48 does not have a defined readiness for covering and is therefore assessed with regard to its residual moisture in accordance with the measurement and assessment standards of DIN 18560/BS 8204*.
  • In this case, PCT Chemie and the Retanol® specialist company assume no responsibility for the readiness for covering.
  • The CM measurement is therefore part of the floor layer's inspection obligation and is carried out by him.

*UK only

POINT LOADS INFORMATIONS

Area load
Point load
2,0 kN/m2
1,0 kN
3,0 kN/m2
2,0 kN
4,0 kN/m2
3,0 kN
5,0 kN/m2
4,0 kN
Flexural strength ≥ F440 mm50 mm55 mm60 mm
  • Specifications, unless otherwise defined, as minimum nominal thickness (without UFH) or minimum pipe cover (with UFH).

AREAS OF APPLICATION

  • For all screeds according to DIN 18560, part 1–7, BS 13892*/ BS 8204*
  • Particularly suitable for reducing cement volumes and CO2 emissions
  • Screed suitable for indoor and outdoor areas as well as in permanently wet areas 

*UK only

DOSAGE & CEMENT QUANTITY

DOSAGE

Compressive strengthCT-C20-F4
Dosage400 ml
Cement quantity40 kg
  • Do not exceed the maximum dosage of 500 ml.
  • The specifications refer to a standard mixing vessel with a net capacity of 200 litres and a filling quantity of approx. 320 kg screed sand.
  • The specification ‘after the X. Day’ does not include the day of installation.
  • The strength class depends on the quality of the screed sand used.
MIXING INSTRUCTIONS
Notes
POINT LOADS INFORMATIONS
AREAS OF APPLICATION