- 30 ml Qualimeter
- Do not exceed the maximum dosage of 50 ml.
- The specifications refer to a standard mixing vessel with a net capacity of 250 litres
QUALIMETER

Qualimeter
The optimum processing aid for higher laying performance. This makes stripping really fun!
- Low pull-off resistance
- High daily output
- Increased homogeneity
DOSAGE & CEMENT QUANTITY
MIXING INSTRUCTIONS
NOTES
Downloads
DOSAGE
MIXING INSTRUCTIONS
- The specifications refer to a standard mixing vessel with a net capacity of 250 litres
- Fill the screed machine half full with sand and the entire amount of cement.
- Add Qualimeter to the first mixing water (usually 5-10 litres), then fill the machine completely.
- Gradually add the required amount of residual water until a stiff-plastic consistency is achieved.
SAND, WATER, CEMENT
- Grading curve: according to DIN 1045-2 A/B / BS 13139*, 0–8 mm
- W/C value: max. 0,6
- Use of cements according to the PCT cement release list
*UK only
PROCESSING INSTRUCTIONS
- Processing +5 °C to +28 °C
- Shake canister every 30 minutes.
- Only use with products from PCT Chemie.
- Do not mix with other screed additives
- Never reactivate screed that has already set with water
Airing
- If the air humidity is 55 % or higher, ventilate 3-4 times a day for 20-30 minutes 24 hours after screed installation in order to achieve readiness for covering.
- If the humidity is below 55%, contact PCT technical support to avoid cupping etc.
Protective instructions during and after installation
- We recommend our PROTEC-ES/SP product to protect against drying out too quickly, depending on the floor covering. We recommend consulting the PCT technical support team.
- Protect the screed against rapid drying of the surface due to draughts, sunlight and low humidity.
- Large window fronts and floor-level glass façade areas should be darkened if necessary.
- Cover screeds in outdoor areas or enclose areas to be covered. Contact PCT technical support if screed is to be laid outdoors.
CM MEASUREMENT
- A Qualimeter screed without an indication of readiness for covering is carried out in accordance with the measurement and assessment standards of DIN 18560/BS 8204*.
- In this case, PCT Chemie and the Retanol® specialist company are not responsible for the readiness for covering.
- The CM measurement is therefore carried out as standard by the floor layer as part of his inspection obligation.
*UK only
DOSAGE & CEMENT QUANTITY
DOSAGE
- 30 ml Qualimeter
- Do not exceed the maximum dosage of 50 ml.
- The specifications refer to a standard mixing vessel with a net capacity of 250 litres
MIXING INSTRUCTIONS
NOTES
Downloads