RETANOL® XTHINN NEATHERM

Retanol® Xthinn NeaTherm
With guaranteed very high early and final strengths of C40 N/mm² , Retanol® Xthinn Neatherm is a thin layer, low shrinkage cement screed for use over underfloor heating. Retanol® Xthinn Neatherm requires only 20 mm coverage on top of the pipe and can be installed at 30 mm overall thickness. Tile floor finishes can be installed after 2 days and all other floor finishes after 3 days (or after 6 days over heated screeds) thus ensuring rapid construction progress, and this thin layer screed reduces the weight per metre2 by more than 50%.
Drying Times
after the 2nd **/3rd -6th * dayCompressive and flexural strength
CT-C40-F6Foot traffic
after 24 hoursNormal site traffic
after 48 hoursCommisioning UFH
after 24 hoursMinimum nominal thickness 2 kN/m²
from 30 mm/20 mm* pipe cover/nub plateSurface strength
≥ 1,5 N/mm²Shrinkage
SW 2 (SW 1 with Agent X®)Energy efficiency class
EC 3Certification
DGNB conformity, EC1 Plus according to Emicode, emission-tested (TÜV Rheinland)
DOSAGE & CEMENT QUANTITY
MIXING INSTRUCTIONS
Notes
POINT LOADS INFORMATIONS
AREAS OF APPLICATION
Downloads
DOSAGE
| Compressive strength | CT-C40-F6 |
| Dosage | 400 ml |
| Cement quantity | 62,5 kg |
| Commisioning cycle | 5 days |
*with underfloor heating/bubble slab
**for ceramic coverings
- Do not exceed the maximum dosage of 500 ml.
- The specifications refer to a standard mixing vessel with a net capacity of 200 litres and a filling quantity of approx. 320 kg screed sand.
- The strength class depends on the quality of the screed sand used.
- The specification ‘after the X. Day’ does not include the day of installation.
- The specification ‘after x hours’ begins after the last square metre of screed has been laid.
MIXING INSTRUCTIONS
- Shake the container well to mix the Retanol® Xthinn NeaTherm additive to a consistent colour before use, and then shake as required throughout the installation to maintain the consistency of the liquid (every 30 mins).
- Fill half of mixing vessel with 0-4 mm screeding sand and required cement.
- Add Retanol® Xthinn NeaTherm to the first mixing water (usually 5-10 litres), then fill the machine completely.
- Gradually add the required amount of residual water until a stiff-plastic consistency is achieved.
- Let the screed mix for a full 2 minutes.
SAND, WATER, CEMENT
- Grading curve: Sand must be according to DIN 1045-2 A/B / BS 13139*,
for the production of screed concrete,
0-4 mm: for a pipe cover min of 20 mm - W/C value: Min 0,4, max. 0,6
- Cement: Use of cement grade 42.5 R/N according to PCT cement release list
*UK only
PROCESSING INSTRUCTIONS
- Working time: 45 minutes
- Finishing time: 60 minutes
- Outside temperature: +5 °C to +28 °C for screed, environment and substrate
- Do not mix with other screed additives
- Never reactivate screed that has already set with water
Airing
- If the air humidity is 55 % or higher, ventilate 3-4 times a day for 20-30 minutes 24 hours after screed installation in order to achieve readiness for covering.
- If the humidity is below 55%, contact PCT technical support to avoid cupping etc.
CM MEASUREMENT
- A Retanol® screed is considered a proprietary screed within its first 56 days after installation , it can not be tested with a RH test, it must be tested with a calcium carbide method before covering. Can be tested and approved by PCT Chemie in regard of rest mouisture by PCT Chemie in form of a CM measurement.
- The CM measurement, including the issuing of a guarantee declaration and the assumption of the warranty, can be ordered free of charge from PCT Chemie during this period by the Retanol® specialist company, floor layers, tilers or the client. Further information on the release of the screed can be found on our homepage under ‘Guarantee’ (EU only).
- After 56 days, the Retanol® screed is assessed according to the standard values of DIN 18560/BS-8203*.
*UK only
Protective instructions during and after installation
- We recommend our PROTEC-ES/SP product to protect against drying out too quickly, depending on the floor covering. We recommend consulting the PCT technical support team.
- Protect the screed against rapid drying of the surface due to draughts, sunlight and low humidity.
- Large window fronts and floor-level glass façade areas should be darkened if necessary.
- Cover screeds in outdoor areas or enclose areas to be covered. Contact PCT technical support if screed is to be laid outdoors.
SPECIAL INSTRUCTIONS
- Installation only by trained and approved applicators
- Insulation material compressibility ≤ 2 mm
- Insulation thickness maximum 80 mm
- Thin-layer screed systems influence the natural resonance behaviour
- The installation of wooden floor coverings, especially solid wood, only after consultation with the PCT technical support team
POINT LOADS INFORMATIONS
| Area load Point load | 2,0 kN/m2 1,0 kN | 3,0 kN/m2 2,0 kN | 4,0 kN/m2 3,0 kN | 5,0 kN/m2 4,0 kN |
| Flexural strength ≥ F6 (with UFH) | 20 mm*** | 20 mm*** | 40 mm | 45 mm |
| Flexural strength ≥ F6 (without UFH) | 30 mm | 30 mm |
*** Pipe cover
- Unless otherwise defined, data as minimum nominal thickness (without UFH) or minimum pipe cover (with UFH).
AREAS OF APPLICATION
- For all screeds according to DIN 18560, part 1–7, BS 13892*/BS 8204*
- Particularly suitable for high-strength screeds with a fast readiness for covering
- Screed suitable for indoor and outdoor areas as well as in permanently wet areas
*UK only
DOSAGE & CEMENT QUANTITY
DOSAGE
| Compressive strength | CT-C40-F6 |
| Dosage | 400 ml |
| Cement quantity | 62,5 kg |
| Commisioning cycle | 5 days |
*with underfloor heating/bubble slab
**for ceramic coverings
- Do not exceed the maximum dosage of 500 ml.
- The specifications refer to a standard mixing vessel with a net capacity of 200 litres and a filling quantity of approx. 320 kg screed sand.
- The strength class depends on the quality of the screed sand used.
- The specification ‘after the X. Day’ does not include the day of installation.
- The specification ‘after x hours’ begins after the last square metre of screed has been laid.
MIXING INSTRUCTIONS
Notes
POINT LOADS INFORMATIONS
AREAS OF APPLICATION
Downloads